English Manual: Super Power Series 60-80
25/03/2004
15
TROUBLE SHOOTING GUIDE
Before contacting your nearest distributor please check the following list for probable causes
PROBLEM PLEASE CHECK
THRUSTER NOT OPERATING
Check correct electric motor voltage check cables
No main power check batteries power on/off switch
check batteries
check fuse
Control Panel check if panel is switched on (green LED on?)
Relay not functioning check wiring and signal relay
Relay clicking Insufficient voltage – check batteries
RELAY FAILURE
Incorrect or damaged batteries Control batteries for size and condition
(see manual for recommended size)
Excessive voltage drop Attain a min 10.8V at relay when operating 12V system
Attain a min 21.6V at relay when operating a 24V system
Battery cable section too small – see manual.
Voltage losses at cable connections
LACK OF THRUST
Low battery power check battery condition and charge
Missing or damaged propeller check propellers
PROPELLORS TOUCHING TUNNEL
Drive leg incorrectly aligned in tunnel Align drive leg in tunnel
Modify fixing holes in necessary
STEEL TUNNELS
Incorrect mounting of electric motor check tunnel Dia inside and outside are as recommended